Short description
Import measurement data in database, and create rttf-files when automatic run is active.
Condition
New measurement data incoming
Postcondition
Measurement data in database, and rttf-file is created (if automatic run is active)
Rules
- Background function (runs automatically in the background when new measurement data comes in)
- If for one site an automatic run is active, it creates for each cycle a rttf-file in the input directory for this run. The length of the cycle (cycletime) is defined by the administrator.
Notes
-Parallel processes must be allowed.
- The rttf-files could be valid only for one site.
- It is possible that the measurement files contains data which has a measurement interval (i.e. length of measurement time interval) which is longer than the cycletime. In this case several rttf-files should be produced, each being valid for one interval with length cycletime and all together covering the measurement interval.
Activity |
Relations